Signals.Propagation

A calibrated dimensionless factor constrained to the interval [0, 1].

  • value : ℝ
  • nonnegative : 0 ≤ self.value
  • le_one : self.value ≤ 1
Instances For
    theorem Signals.Propagation.mul_le_one {left right : ℝ} (left_le_one : left ≤ 1) (right_nonnegative : 0 ≤ right) (right_le_one : right ≤ 1) :
    left * right ≤ 1

    Multiplication of independent efficiency or transmission factors.

    Whether a link is coupled in the far field or near field.

    Instances For

      Antenna and geometry factors for a radiative link.

      Near-field operation is represented separately from far-field operation. The reactive fraction records energy stored locally rather than silently treating near-field coupling as lossless propagation.

      Instances For

        The product of antenna, impedance, aperture, alignment, and radiation factors.

        Instances For

          All coupling factors give a nonnegative total transfer factor.

          Independent coupling factors cannot amplify delivered power.

          The near-field bookkeeping leaves no more than unit total energy for stored and radiated components.

          Bulk constitutive loss represented by a nonnegative attenuation coefficient and a separately calibrated transmission factor.

          Instances For

            Power reflection, transmission, and absorption at an interface.

            The conservation equation is data supplied by the interface model; it does not assume that a material boundary is reflection-free.

            Instances For

              Interface transmission is bounded by one when reflection and absorption are nonnegative.

              Propagation strategies discussed in the source communications design.

              Instances For

                A link budget with explicit near/far-field coupling and propagation losses.

                Instances For

                  Power attenuation from the modeled bulk attenuation coefficient.

                  Instances For

                    Bulk attenuation is nonnegative.

                    Nonnegative attenuation cannot increase a link's power.

                    The multiplicative transfer factor for a link budget.

                    Instances For

                      A link transfer factor is nonnegative.

                      A link transfer factor cannot exceed one.

                      Received power after antenna, interface, material, and attenuation losses.

                      Instances For

                        A passive link budget cannot deliver negative received power.

                        Explicit loss factors guarantee received power does not exceed source power.