Documentation

Signals.SemiDirac

Semi-Dirac and optical-pumping models #

The semi-Dirac records below extract the anisotropic low-energy dispersion and pump-response bookkeeping discussed by Ghosh, Bandyopadhyay, and Singh and by Uchoa et al. They are finite conditional models. They do not assert that a lignin-vitrimer, rGO, Proca resonator, graphene layer, or fiber laser realizes these equations, and they do not infer an absolute process power from the papers.

A two-dimensional semi-Dirac dispersion with a linear y direction and a quadratic x direction. The energy scale is normalized so the coefficients have already absorbed the relevant unit conversions.

Instances For
    theorem Signals.Pending.SemiDiracDispersion.dispersion_holds (dispersion : SemiDiracDispersion) :
    dispersion.energy ^ 2 = (dispersion.momentumX ^ 2 / (2 * dispersion.mass)) ^ 2 + (dispersion.linearVelocity * dispersion.momentumY) ^ 2

    The semi-Dirac energy shell is the supplied anisotropic dispersion law.

    theorem Signals.Pending.SemiDiracDispersion.quadratic_axis_energy_squared (dispersion : SemiDiracDispersion) (momentumY_zero : dispersion.momentumY = 0) :
    dispersion.energy ^ 2 = (dispersion.momentumX ^ 2 / (2 * dispersion.mass)) ^ 2

    Along the quadratic axis, the model energy is quadratic in momentum when there is no momentum on the linear axis.

    theorem Signals.Pending.SemiDiracDispersion.linear_axis_energy_squared (dispersion : SemiDiracDispersion) (momentumX_zero : dispersion.momentumX = 0) :
    dispersion.energy ^ 2 = (dispersion.linearVelocity * dispersion.momentumY) ^ 2

    Along the linear axis, the model energy is linear in the absolute momentum at the level of squared energy.

    A pump-dependent anisotropic response, stored as a conditional linear response law. The pump is a nonnegative optical power and the two response coefficients are measured or supplied model inputs.

    Instances For

      Optical pumping changes the quadratic-axis response according to the supplied calibration law.

      Optical pumping changes the linear-axis response according to the supplied calibration law.

      A positive pump and strictly positive calibrated gain increase an axis response.

      theorem Signals.Pending.SemiDiracOpticalResponse.linear_response_increases (response : SemiDiracOpticalResponse) (pumpPower_pos : 0 < response.pumpPower.watts) (gain_pos : 0 < response.linearResponseGain) :
      response.linearResponse < response.linearSignal

      The corresponding monotonicity result for the linear axis.

      Power allocated to an optical control chain. fiberLaserPower is the laser electrical/optical input budget, while the remaining powers are declared loads or losses.

      Instances For

        The declared fiber-laser input supplies all listed control, process, and loss powers.

        No declared process or control output can exceed the fiber-laser input.

        A calibrated absorbed-power requirement gives a necessary lower bound on fiber-laser power after an explicit end-to-end efficiency.

        Instances For

          The process threshold is met only when the declared absorbed power reaches its calibrated requirement.

          Under a positive end-to-end efficiency, meeting the calibrated threshold requires at least threshold divided by efficiency at the fiber-laser input.